{"id":1171,"date":"2021-04-15T18:14:14","date_gmt":"2021-04-15T09:14:14","guid":{"rendered":"https:\/\/www.itec-es.co.jp\/en\/wordpress\/?post_type=ufaq&#038;p=1171"},"modified":"2022-06-14T17:38:04","modified_gmt":"2022-06-14T08:38:04","slug":"q-11-%e8%a9%a6%e9%a8%93%e8%a3%85%e7%bd%ae%e3%81%af%e3%80%81%e3%81%a9%e3%81%ae%e3%82%88%e3%81%86%e3%81%aa%e7%89%a9%e3%81%8c%e8%a3%bd%e4%bd%9c%e5%8f%af%e8%83%bd%e3%81%a7%e3%81%99%e3%81%8b%ef%bc%9f","status":"publish","type":"ufaq","link":"https:\/\/www.itec-es.co.jp\/en\/ufaq\/q-11-%e8%a9%a6%e9%a8%93%e8%a3%85%e7%bd%ae%e3%81%af%e3%80%81%e3%81%a9%e3%81%ae%e3%82%88%e3%81%86%e3%81%aa%e7%89%a9%e3%81%8c%e8%a3%bd%e4%bd%9c%e5%8f%af%e8%83%bd%e3%81%a7%e3%81%99%e3%81%8b%ef%bc%9f\/","title":{"rendered":"Q.11 What kind of test system can be manufactured?"},"content":{"rendered":"<div  class=\"ewd-ufaq-faq-list ewd-ufaq-page-type-distinct\" id='ewd-ufaq-faq-list'>\n\n\t<input type='hidden' name='show_on_load' value='' id='ewd-ufaq-show-on-load' \/>\n<input type='hidden' name='include_category' value='' id='ewd-ufaq-include-category' \/>\n<input type='hidden' name='exclude_category' value='' id='ewd-ufaq-exclude-category' \/>\n<input type='hidden' name='orderby' value='title' id='ewd-ufaq-orderby' \/>\n<input type='hidden' name='order' value='asc' id='ewd-ufaq-order' \/>\n<input type='hidden' name='post_count' value='-1' id='ewd-ufaq-post-count' \/>\n<input type='hidden' name='current_url' value='\/en\/wp-json\/wp\/v2\/ufaq\/1171' id='ewd-ufaq-current-url' \/>\n\t\n\t\n\t<div class='ewd-ufaq-faqs'>\n\n\t\t<div  class=\"ewd-ufaq-faq-div ewd-ufaq-faq-column-count-one ewd-ufaq-faq-responsive-columns- ewd-ufaq-faq-display-style-default ewd-ufaq-can-be-toggled\" id='ewd-ufaq-post-1171-diRvpMnkH8' data-post_id='1171'>\n\n\t<div class='ewd-ufaq-faq-title ewd-ufaq-faq-toggle'>\n\t\n\t<a class='ewd-ufaq-post-margin'  href='#' role=\"button\">\n\n\t\t<div class='ewd-ufaq-post-margin-symbol ewd-ufaq-'>\n\t\t\t<span >A<\/span>\n\t\t<\/div>\n\n\t\t<div class='ewd-ufaq-faq-title-text'>\n\n\t\t\t<h4>\n\t\t\t\tQ.11 What kind of test system can be manufactured?\t\t\t<\/h4>\n\n\t\t<\/div>\n\n\t\t<div class='ewd-ufaq-clear'><\/div>\n\n\t<\/a>\n\t\n<\/div>\n\t\n\t<div class='ewd-ufaq-faq-body ' >\n\n\t\t\n\t\t\t\n\t\t\n\t\t\t<div class='ewd-ufaq-post-margin ewd-ufaq-faq-post'>\n\t\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>For supercritical processing, the following items are required at a minimum: a pressure vessel for the material to be processed (&#8220;extractor&#8221; shown on the right in Q.12), a pump that pressurizes to about 5 to 45 MPa, a heater that keeps the temperature at 20 to 150\u00b0C, a separator to separate the extracted material from the CO\u2082, and a CO\u2082 cylinder.<\/p>\n\n\n\n<p>To manufacture the equipment, specifications such as the capacity of the pressure vessel, design temperature, design pressure, and flow rate are first determined according to the treatment purpose and treatment volume. For example, if you want to observe the supercritical condition (~ 27MPa), use the view cell with a glass window shown in the Q.2. The system can be fabricated from 5 ml or more. In the case of a test system, cooling and recovery of carbon dioxide as shown in Q.12 is not generally done for economic reasons.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"215\" height=\"240\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_02.jpg\" alt=\"\" class=\"wp-image-1172\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-4 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>Please refer to Q.2 for the apparatus used in our trial test. The following are examples of typical equipment manufactured by our company.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Pilot plant<\/h5>\n\n\n\n<h6 class=\"wp-block-heading\">50MPa\u300180\u2103\u300130 Liter<\/h6>\n<\/div>\n<\/div>\n<\/div>\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t<\/div>\n\n<\/div>\n\t<\/div>\n\n\t\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A Q.11 What kind of test syste\u2026<\/p>\n","protected":false},"author":2,"comment_status":"closed","ping_status":"closed","template":"","ufaq-category":[27],"ufaq-tag":[],"class_list":["post-1171","ufaq","type-ufaq","status-publish","hentry","ufaq-category-co2-souti"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/ufaq\/1171","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/ufaq"}],"about":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/types\/ufaq"}],"author":[{"embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/comments?post=1171"}],"wp:attachment":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/media?parent=1171"}],"wp:term":[{"taxonomy":"ufaq-category","embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/ufaq-category?post=1171"},{"taxonomy":"ufaq-tag","embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/ufaq-tag?post=1171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}