{"id":327,"date":"2021-04-01T16:21:39","date_gmt":"2021-04-01T07:21:39","guid":{"rendered":"https:\/\/www.itec-es.co.jp\/en\/wordpress\/?post_type=products&#038;p=327"},"modified":"2022-06-09T15:57:20","modified_gmt":"2022-06-09T06:57:20","slug":"pro_co2_05","status":"publish","type":"products","link":"https:\/\/www.itec-es.co.jp\/en\/products\/pro_co2_05\/","title":{"rendered":"Various supercritical CO\u2082 testing apparatus"},"content":{"rendered":"\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"has-text-align-center wp-block-heading\">Various supercritical CO\u2082 testing apparatus<\/h1>\n\n\n\n<p class=\"has-text-align-center has-medium-font-size\"><strong>Customized for a wide variety of uses<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center\">The following is a list of the various types of apparatus we have worked on.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-2 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Wafer Cleaning Processor<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"443\" height=\"381\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_01.jpg\" alt=\"\" class=\"wp-image-337\"\/><figcaption>Apparatus for performing supercritical treatment tests on anodized aluminum.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>25MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>100\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Volume<\/strong><\/strong><\/td><td>7L<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Supercritical CO\u2082 surface treatment apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"460\" height=\"381\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_02.jpg\" alt=\"\" class=\"wp-image-334\"\/><figcaption>Supercritical plating apparatus<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>15MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>120\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Volume<\/strong><\/strong><\/td><td>7L<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Supercritical CO\u2082 surface treatment apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"460\" height=\"363\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_03.jpg\" alt=\"\" class=\"wp-image-341\"\/><figcaption>Supercritical plating apparatus<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>15MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>100\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Volume<\/strong><\/strong><\/td><td>20L<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Supercritical CO\u2082 surface treatment apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"460\" height=\"363\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_04.jpg\" alt=\"\" class=\"wp-image-342\"\/><figcaption>Supercritical plating apparatus<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>15MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>100\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Volume<\/strong><\/strong><\/td><td>0.43L<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-4 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Dry cleaning apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"460\" height=\"330\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_05.jpg\" alt=\"\" class=\"wp-image-343\"\/><figcaption>Supercritical dry cleaning apparatus<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>12MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>60\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Volume<\/strong><\/strong><\/td><td>112L<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Silicon wafer cleaning test apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"460\" height=\"330\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_06.jpg\" alt=\"\" class=\"wp-image-344\"\/><figcaption>Supercritical silicon wafer cleaning apparatus<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>34MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>100\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Volume<\/strong><\/strong><\/td><td>20ml<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-5 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Multi-use testing apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"354\" height=\"329\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_07.jpg\" alt=\"\" class=\"wp-image-345\"\/><figcaption>Supercritical testing apparatus<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>29MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>150\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Volume<\/strong><\/td><td>300ml<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Supercritical CO\u2082 gas turbine cycle test apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"457\" height=\"329\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_08.jpg\" alt=\"\" class=\"wp-image-346\"\/><figcaption>Loop-type testing apparatus for measuring heat exchanger performance near the critical point<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>15MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>350\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Flow rate<\/strong><\/td><td>646kg\/Hr<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-6 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Supercritical CO\u2082 corrosion testing Equipment<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"380\" height=\"300\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_09.jpg\" alt=\"\" class=\"wp-image-349\"\/><figcaption>Equipment for verifying metal corrosion under supercritical conditions<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>15MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>650\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Flow rate<\/strong><\/strong><\/td><td>6kg\/hr<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Heat exchanger two-phase flow test apparatus<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"380\" height=\"300\" src=\"https:\/\/www.itec-es.co.jp\/en\/wordpress\/wp-content\/uploads\/2021\/04\/img_pro_co2_05_10.jpg\" alt=\"\" class=\"wp-image-350\"\/><figcaption>Apparatus to verify the behavior of CO\u2082 in a heat exchanger near the critical point<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design pressure<\/strong><\/td><td>15MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Design temperature<\/strong><\/td><td>50\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong><strong>Flow rate<\/strong><\/strong><\/strong><\/td><td>6kg\/hr<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Various supercritical CO\u2082 test\u2026<\/p>\n","protected":false},"author":2,"featured_media":852,"menu_order":15,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"products_cat":[4],"class_list":["post-327","products","type-products","status-publish","format-standard","has-post-thumbnail","hentry","products_cat-co2"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/products\/327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/types\/products"}],"author":[{"embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/comments?post=327"}],"version-history":[{"count":23,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/products\/327\/revisions"}],"predecessor-version":[{"id":3645,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/products\/327\/revisions\/3645"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/media\/852"}],"wp:attachment":[{"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/media?parent=327"}],"wp:term":[{"taxonomy":"products_cat","embeddable":true,"href":"https:\/\/www.itec-es.co.jp\/en\/wp-json\/wp\/v2\/products_cat?post=327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}